ENGINE
Industrial 4 stroke water cooled diesel engine complete with air, fuel and oil filters, electric starting and charging equipment, engine protection against low oil pressure, high engine temperature and low water level. Rated in accordance with ISO 3046 / ISO 8528. Mechanical governor is fitted up to TAD731G, and Electronic governor is fitted thereafter.
ALTERNATOR
Brushless, self exciting, self regulating, screen protected, drip proof rated in accordance with BS 4999/5000. Voltage regulation maintained within ± 1.5% from no load to full load, between 0.8 lagging and unity. All standard voltages available. Radio suppression to BS 800.
COOLING
Radiator and cooling fan complete with protection guards, designed to cool engine at specified output in air temperatures up to 45°C. Radiators suitable for higher temperatures are available.
ELECTRICAL SYSTEM
12 Volt up to TAD731GE and 24 Volt thereafter. Axial type starter motor, battery charging alternator, high capacity lead acid battery, battery tray mounted on the generator baseframe, and heavy duty interconnecting cable with terminations.
EXHAUST SYSTEM
Heavy duty industrial exhaust silencer with flexible piping.
CONSTRUCTION
The generator is mounted on a heavy duty fabricated steel baseframe, complete with lifting eyes. The engine is coupled to the alternator via an SAE flange, connecting the engine flywheel to the alternator rotor. Anti-Vibration Mountings are fitted between the engine/alternator feet and the baseframe.
FUEL SYSTEM
The baseframe incorporates a daily service fuel tank which is complete with contents gauge, filler cap, filter with breather and strainer, fuel feed and return lines, drain plug and vent pipe.
CONTROL PANEL
Set mounted totally enclosed sheet steel control panel complete with 3 Ammeters, Voltmeter with selector switch, 3 Current Transformers, Frequency / RPM meter, Hours Run Counter, Water Temperature Gauge, Oil Pressure Gauge, Battery Ammeter, Key Start Module for Start / Stop operation. Shutdown and Protection Devices for Low Oil Pressure and High Engine Temperature.
MAIN LINE CIRCUIT BREAKER
3 Pole circuit breaker mounted inside the control panel or on the set in a separate enclosure, with easy access for incoming and outgoing cables. The circuit breaker is complete with thermal and magnetic trips.